Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 14.117
Filtrar
1.
Eur Radiol Exp ; 8(1): 40, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38565836

RESUMO

BACKGROUND: To assess the feasibility and tissue response of using a gold nanoparticle (AuNP)-integrated silicone-covered self-expandable metal stent (SEMS) for local hyperthermia in a rat esophageal model. METHODS: The study involved 42 Sprague-Dawley rats. Initially, 6 animals were subjected to near-infrared (NIR) laser irradiation (power output from 0.2 to 2.4 W) to assess the in vitro heating characteristics of the AuNP-integrated SEMS immediately after its placement. The surface temperature of the stented esophagus was then measured using an infrared thermal camera before euthanizing the animals. Subsequently, the remaining 36 animals were randomly divided into 4 groups of 9 each. Groups A and B received AuNP-integrated SEMS, while groups C and D received conventional SEMS. On day 14, groups A and C underwent NIR laser irradiation at a power output of 1.6 W for 2 min. By days 15 (3 animals per group) or 28 (6 animals per group), all groups were euthanized for gross, histological, and immunohistochemical analysis. RESULTS: Under NIR laser irradiation, the surface temperature of the stented esophagus quickly increased to a steady-state level. The surface temperature of the stented esophagus increased proportionally with power outputs, being 47.3 ± 1.4 °C (mean ± standard deviation) at 1.6 W. Only group A attained full circumferential heating through all layers, from the epithelium to the muscularis propria, demonstrating marked apoptosis in these layers without noticeable necroptosis. CONCLUSIONS: Local hyperthermia using the AuNP-integrated silicone-covered SEMS was feasible and induced cell death through apoptosis in a rat esophageal model. RELEVANCE STATEMENT: A gold nanoparticle-integrated silicone-covered self-expanding metal stent has been developed to mediate local hyperthermia. This approach holds potential for irreversibly damaging cancer cells, improving the sensitivity of cancer cells to therapies, and triggering systemic anticancer immune responses. KEY POINTS: • A gold nanoparticle-integrated silicone-covered self-expanding metal stent was placed in the rat esophagus. • Upon near-infrared laser irradiation, this stent quickly increased the temperature of the stented esophagus. • Local hyperthermia using this stent was feasible and resulted in cell death through apoptosis.


Assuntos
Hipertermia Induzida , Nanopartículas Metálicas , Ratos , Animais , Ouro , Silicones , Estudos de Viabilidade , Ratos Sprague-Dawley , Esôfago , Stents
2.
Front Immunol ; 15: 1342895, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38566997

RESUMO

Excessive fibrous capsule formation around silicone mammary implants (SMI) involves immune reactions to silicone. Capsular fibrosis, a common SMI complication linked to host responses, worsens with specific implant topographies. Our study with 10 patients investigated intra- and inter-individually, reduced surface roughness effects on disease progression, wound responses, chronic inflammation, and capsular composition. The results illuminate the significant impact of surface roughness on acute inflammatory responses, fibrinogen accumulation, and the subsequent fibrotic cascade. The reduction of surface roughness to an average roughness of 4 µm emerges as a promising approach for mitigating detrimental immune reactions, promoting healthy wound healing, and curbing excessive fibrosis. The identified proteins adhering to rougher surfaces shed light on potential mediators of pro-inflammatory and pro-fibrotic processes, further emphasizing the need for meticulous consideration of surface design. The composition of the implant capsule and the discovery of intracapsular HSP60 expression highlight the intricate web of stress responses and immune activation that can impact long-term tissue outcomes.


Assuntos
Inflamação , Próteses e Implantes , Humanos , Silicones , Fibrose , Cicatrização
3.
Environ Sci Technol ; 58(15): 6772-6780, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38577774

RESUMO

The quality of chemical analysis is an important aspect of passive sampling-based environmental assessments. The present study reports on a proficiency testing program for the chemical analysis of hydrophobic organic compounds in silicone and low-density polyethylene (LDPE) passive samplers and hydrophilic compounds in polar organic chemical integrative samplers. The median between-laboratory coefficients of variation (CVs) of hydrophobic compound concentrations in the polymer phase were 33% (silicone) and 38% (LDPE), similar to the CVs obtained in four earlier rounds of this program. The median CV over all rounds was 32%. Much higher variabilities were observed for hydrophilic compound concentrations in the sorbent: 50% for the untransformed data and a factor of 1.6 after log transformation. Limiting the data to the best performing laboratories did not result in less variability. Data quality for hydrophilic compounds was only weakly related to the use of structurally identical internal standards and was unrelated to the choice of extraction solvent and extraction time. Standard deviations of the aqueous concentration estimates for hydrophobic compound sampling by the best performing laboratories were 0.21 log units for silicone and 0.27 log units for LDPE (factors of 1.6 to 1.9). The implications are that proficiency testing programs may give more realistic estimates of uncertainties in chemical analysis than within-laboratory quality control programs and that these high uncertainties should be taken into account in environmental assessments.


Assuntos
Polietileno , Poluentes Químicos da Água , Polietileno/análise , Poluentes Químicos da Água/análise , Monitoramento Ambiental/métodos , Compostos Orgânicos , Silicones
4.
Sci Adv ; 10(14): eadk5949, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38578991

RESUMO

The transplantation of engineered cells that secrete therapeutic proteins presents a promising method for addressing a range of chronic diseases. However, hydrogels used to encase and protect non-autologous cells from immune rejection often suffer from poor mechanical properties, insufficient oxygenation, and fibrotic encapsulation. Here, we introduce a composite encapsulation system comprising an oxygen-permeable silicone cryogel skeleton, a hydrogel matrix, and a fibrosis-resistant polymer coating. Cryogel skeletons enhance the fracture toughness of conventional alginate hydrogels by 23-fold and oxygen diffusion by 2.8-fold, effectively mitigating both implant fracture and hypoxia of encapsulated cells. Composite implants containing xenogeneic cells engineered to secrete erythropoietin significantly outperform unsupported alginate implants in therapeutic delivery over 8 weeks in immunocompetent mice. By improving mechanical resiliency and sustaining denser cell populations, silicone cryogel skeletons enable more durable and miniaturized therapeutic implants.


Assuntos
Criogéis , Hidrogéis , Camundongos , Animais , Silicones , Alginatos , Oxigênio , Esqueleto , Sobrevivência Celular
5.
Gan To Kagaku Ryoho ; 51(4): 460-462, 2024 Apr.
Artigo em Japonês | MEDLINE | ID: mdl-38644322

RESUMO

Recently, the cases of breast augmentation for cosmetic purposes are rapidly increasing, there are more opportunities to examine for patient with breast augmentation history than before. In some cases, breast cancer screening is difficult due to the effects of breast augmentation. At our clinic, even in cases diagnosed with breast cancer after breast augmentation, we actively perform immediate breast reconstruction using silicone implant. However, it is necessary to consider the condition and type of breast augmentation at the time of diagnosis and also treatment. We will share our algorithm for immediate breast reconstruction using silicone implant for breast cancer after augmentation mammaplasty.


Assuntos
Algoritmos , Implantes de Mama , Neoplasias da Mama , Mamoplastia , Humanos , Neoplasias da Mama/cirurgia , Feminino , Mamoplastia/métodos , Silicones
6.
J Adhes Dent ; 26(1): 93-102, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38602286

RESUMO

PURPOSE: To investigate the influence of contamination and different cleaning methods on resin bonding to cobalt-chro- mium (CoCr) alloy disks. MATERIALS AND METHODS: A total of 160 CoCr disks were divided into 3 groups. The first group (N = 64) was air abraded with alumina particles and contaminated with a silicone disclosing agent and saliva; the second group (N = 64) was air abraded but not contaminated; the third group (N = 32) was neither air abraded nor contaminated. The first two groups were di- vided into 4 subgroups (N = 16) according to the cleaning method: ultrasonic bath in 99% isopropanol, use of a cleaning suspension of zirconium oxide particles, use of a cleaning suspension based on 10-MDP salt, and treatment with atmo- spheric plasma. The third group was divided into 2 subgroups (N = 16): treatment with atmospheric plasma and no treat- ment. All CoCr specimens were bonded to plexiglas tubes filled with a bonding resin that contained phosphate monomer. Tensile bond strength (TBS) was examined by tensile testing after 3 and 150 days of water storage plus 37,500 thermal cy- cles (N = 8). RESULTS: After contamination, TBS was significantly reduced after 150 days of water storage. Groups without air abrasion showed initially low TBS and debonded spontaneously after 150 days of water storage. CONCLUSION: None of the cleaning methods was able to remove saliva and silicone disclosing agent on CoCr-alloy sur- faces. Surface activation by plasma treatment has no long-term effect on the bond strength.


Assuntos
Resinas Compostas , Colagem Dentária , Cimentos de Resina , Ligas , Abrasão Dental por Ar , Propriedades de Superfície , Água , Resistência à Tração , Silicones , Teste de Materiais , Zircônio , Análise do Estresse Dentário
7.
Environ Sci Technol ; 58(15): 6499-6508, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38572580

RESUMO

A social housing estate in Denmark was designated for demolition due to exceedance of guidance values for polychlorinated biphenyls (PCBs) in indoor air. Here, we deployed precleaned silicone wristbands (n = 46) among demolition workers of these contaminated buildings during single workdays while conducting various work tasks. We established a method to analyze all 209 PCBs in wristbands to identify prominent congeners of exposure and evaluate differences between tasks. Wristbands were extracted using microwave-assisted extraction and then concentrated for gas chromatography-tandem mass spectrometry (GC-MS/MS) analysis. Twenty-nine chromatographic peaks representing 37 congeners were detected in every wristband, and tetra-CBs were the dominant homologue group. PCB-66, -44, and -70 were the most abundant congeners measured in worker wristbands, none of which are included within the typical seven indicator or WHO 12 PCBs. Workers who cut PCB-containing sealants had wristbands with the highest PCB concentrations (geometric mean ∑209PCBs = 1963 ng/g wristband), which were followed by those handling concrete elements on the building roof. Additionally, wristbands captured a broader range of PCBs than has been previously measured in air and serum samples. Taken together, our results highlight the importance of total congener analysis in assessing current PCB exposure in demolition work and the utility of wristbands for assessing these exposures.


Assuntos
Bifenilos Policlorados , Humanos , Bifenilos Policlorados/análise , Monitoramento Ambiental , Espectrometria de Massas em Tandem , Silicones
8.
Sci Total Environ ; 927: 172187, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38582107

RESUMO

Plasticizers (PLs) and organophosphate flame retardants (OPFRs) are ubiquitous in the environment due to their widespread use and potential for leaching from consumer products. Environmental exposure is a critical aspect of the human exposome, revealing complex interactions between environmental contaminants and potential health effects. Silicone wristbands (SWBs) have emerged as a novel and non-invasive sampling device for assessing personal external exposure. In this study, SWBs were used as a proxy to estimate personal dermal adsorption (EDdermal) to PLs and OPFRs in Belgian participants for one week; four morning urine samples were also collected and analyzed for estimated daily intake (EDI). The results of the SWBs samples showed that all the participants were exposed to these chemicals, and the exposure was found to be highest for the legacy and alternative plasticizers (LP and AP), followed by the legacy and emerging OPFRs (LOPFR and EOPFR). In urine samples, the highest levels were observed for metabolites of diethyl phthalate (DEP), di-isobutyl phthalate (DiBP) and di-n-butyl phthalate (DnBP) among LPs and di(2-ethylhexyl) terephthalate (DEHT) for APs. Outliers among the participants indicated that there were other sources of exposure that were not identified. Results showed a significant correlation between EDdermal and EDI for DiBP, tris (2-butoxyethyl) phosphate (TBOEP) and triphenyl phosphate (TPhP). These correlations indicated their suitability for predicting exposure via SWB monitoring for total chemical exposure. The results of this pilot study advance our understanding of SWB sampling and its relevance for predicting aggregate environmental chemical exposures, while highlighting the potential of SWBs as low-cost, non-invasive personal samplers for future research. This innovative approach has the potential to advance the assessment of environmental exposures and their impact on public health.


Assuntos
Exposição Ambiental , Monitoramento Ambiental , Retardadores de Chama , Organofosfatos , Plastificantes , Silicones , Retardadores de Chama/análise , Plastificantes/análise , Humanos , Exposição Ambiental/estatística & dados numéricos , Exposição Ambiental/análise , Organofosfatos/urina , Bélgica , Adulto , Poluentes Ambientais/urina , Masculino , Feminino
9.
Top Curr Chem (Cham) ; 382(2): 11, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38589726

RESUMO

Silicone surfactants have garnered significant research attention owing to their superior properties, such as wettability, ductility, and permeability. Small-molecular silicone surfactants with simple molecular structures outperform polymeric silicone surfactants in terms of surface activity, emulsification, wetting, foaming, and other areas. Moreover, silicone surfactants with small molecules exhibit a diverse and rich molecular structure. This review discusses various synthetic routes for the synthesis of different classes of surfactants, including single-chain, "umbrella" structure, double chain, bolaform, Gemini, and stimulus-responsive surfactants. The fundamental surface/interface properties of the synthesized surfactants are also highlighted. Additionally, these surfactants have demonstrated enormous potential in agricultural synergism, drug delivery, mineral flotation, enhanced oil recovery, separation, and extraction, and foam fire-fighting.


Assuntos
Silicones , Tensoativos , Tensoativos/química , Propriedades de Superfície , Estrutura Molecular
10.
Int J Prosthodont ; 37(7): 127-131, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38498864

RESUMO

PURPOSE: To evaluate and compare the fracture resistance and elastic modulus of 3D-printed post and core systems and fiber posts and composite cores. MATERIALS AND METHODS: Endodontic treatment was performed on 30 mandibular premolars, and post space preparation was performed. The teeth were then randomly divided into two groups (n = 15 per group): the 3D-printed (3DP) group and the fiber post and composite core (FPC) group. In the FPC group, fiber posts (Cytec Blanco 43.604, Hahnenkratt) were bonded with resin cement (RelyX U200, 3M), and the composite core dimension was standardized with a silicone index. In the 3DP group, the impression of the post space for each specimen was taken with pattern resin (Pattern Resin, GC America), and the coronal core was produced with the same silicone index. The impressions of the posts and cores were scanned, and then the custom post and core structures were fabricated from permanent crown resin material (Permanent Crown Resin, Formlabs) with a 3D printer (Form3B, Formlabs). Specimens were subjected to load tests with a universal testing machine (M500-25AT, Testometric). After fracture occurred, the fracture force and elastic modulus were calculated. The data were analyzed by independent sample t test (α = .05) Results: There was no statistically significant difference between the two groups in terms of peak fracture force (P = .626) and elastic modulus (P = .125), and no catastrophic root fractures were observed in either group. CONCLUSIONS: The fracture resistance of endodontically treated teeth was not significantly influenced by the post material. 3D-printed, custom-made resin posts were as effective as fiber glass posts with regard to fracture resistance.


Assuntos
Técnica para Retentor Intrarradicular , Fraturas dos Dentes , Dente não Vital , Humanos , Resinas Compostas/química , Coroas , Vidro/química , Cimentos de Resina/química , Silicones , Impressão Tridimensional , Dente não Vital/terapia , Análise do Estresse Dentário
11.
Harefuah ; 163(3): 191-195, 2024 Mar.
Artigo em Hebraico | MEDLINE | ID: mdl-38506363

RESUMO

INTRODUCTION: POST-COVID SYNDROME, SICK BUILDING SYNDROME, SILICONE BREAST SYNDROME, CHRONIC FATIGUE SYNDROME, FIBROMYALGIA; AUTOIMMUNITY TO THE AUTONOMIC NERVOUS SYSTEM.


Assuntos
COVID-19 , Síndrome de Fadiga Crônica , Fibromialgia , Síndrome do Edifício Doente , Humanos , Síndrome de Fadiga Crônica/etiologia , Fibromialgia/etiologia , Autoimunidade , Silicones , Sistema Nervoso Autônomo
12.
Int J Mol Sci ; 25(6)2024 Mar 09.
Artigo em Inglês | MEDLINE | ID: mdl-38542137

RESUMO

Breast cancer is the most common cancer in women globally, often necessitating mastectomy and subsequent breast reconstruction. Silicone mammary implants (SMIs) play a pivotal role in breast reconstruction, yet their interaction with the host immune system and microbiome remains poorly understood. This study investigates the impact of SMI surface topography on host antimicrobial responses, wound proteome dynamics, and microbial colonization. Biological samples were collected from ten human patients undergoing breast reconstruction with SMIs. Mass spectrometry profiles were analyzed for acute and chronic wound proteomes, revealing a nuanced interplay between topography and antimicrobial response proteins. 16S rRNA sequencing assessed microbiome dynamics, unveiling topography-specific variations in microbial composition. Surface topography alterations influenced wound proteome composition. Microbiome analysis revealed heightened diversity around rougher SMIs, emphasizing topography-dependent microbial invasion. In vitro experiments confirmed staphylococcal adhesion, growth, and biofilm formation on SMI surfaces, with increased texture correlating positively with bacterial colonization. This comprehensive investigation highlights the intricate interplay between SMI topography, wound proteome dynamics, and microbial transmission. The findings contribute to understanding host-microbe interactions on SMI surfaces, essential for optimizing clinical applications and minimizing complications in breast reconstruction.


Assuntos
Anti-Infecciosos , Implantes de Mama , Neoplasias da Mama , Humanos , Feminino , Silicones , Implantes de Mama/efeitos adversos , Neoplasias da Mama/cirurgia , Proteoma , RNA Ribossômico 16S/genética , Mastectomia , Fibrose
13.
Biofouling ; 40(2): 177-192, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38465991

RESUMO

Silicone materials are widely used in fouling release coatings, but developing eco-friendly protection via biosourced coatings, such as polyhydroxyalcanoates (PHA) presents a major challenge. Anti-bioadhesion properties of medium chain length PHA and short chain length PHA films are studied and compared with a reference Polydimethylsiloxane coating. The results highlight the best capability of the soft and low-roughness PHA-mcl films to resist bacteria or diatoms adsorption as compared to neat PDMS and PHBHV coatings. These parameters are insufficient to explain all the results and other properties related to PHA crystallinity are discussed. Moreover, the addition of a low amount of PEG copolymers within the coatings, to create amphiphilic coatings, boosts their anti-adhesive properties. This work reveals the importance of the physical or chemical ambiguity of surfaces in their anti-adhesive effectiveness and highlights the potential of PHA-mcl film to resist the primary adhesion of microorganisms.


Assuntos
Diatomáceas , Poli-Hidroxialcanoatos , Biofilmes , Silicones/química , Adsorção
14.
Biofouling ; 40(2): 209-222, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38500010

RESUMO

This study explores the potential of geranium essential oil as a natural solution for combating marine biofouling, addressing the environmental concerns associated with commercial antifouling coatings. Compounds with bactericidal activities were identified by 13Carbon nuclear magnetic resonance (13C NMR). Thermogravimetric analysis (TGA) revealed minimal impact on film thermal stability, maintaining suitability for antifouling applications. The addition of essential oil induced changes in the morphology of the film and Fourier transform infrared spectroscopy (FTIR) analysis indicated that oil remained within the film. Optical microscopy showed an increase in coating porosity after immersion in a marine environment. A total of 18 bacterial colonies were isolated, with Psychrobacter adeliensis and Shewanella algidipiscicola being the predominant biofilm-forming species. The geranium essential oil-based coating demonstrated the ability to reduce the formation of Psychrobacter adeliensis biofilms and effectively inhibit macrofouling adhesion for a duration of 11 months.


Assuntos
Incrustação Biológica , Geranium , Óleos Voláteis , Psychrobacter , Biofilmes , Incrustação Biológica/prevenção & controle , Óleos Voláteis/farmacologia , Óleos de Silicone/farmacologia , Silicones
15.
Clin Oral Investig ; 28(4): 233, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38556612

RESUMO

OBJECTIVES: Reconstruction of a three-dimensional jaw position determined by a bite recording is an important aspect of prosthetic therapy. Different materials are used for this purpose. In the dental technical workflow, recordings are used to mount a lower jaw cast in a patient-like spatial position relative to the upper jaw cast. We evaluated the accuracy of positioning under the influence of different jaw positions and materials. MATERIALS AND METHODS: In an experimental setup, comprising an articulator, a pair of metal casts, and an optoelectronic measurement system, the spatial position of the incisal point and two condylar points were measured. To evaluate the accuracy of repeated repositioning of casts in the technical workflow, 324 measurements were taken from 108 recordings, consisting of silicone bite-stops made of addition curing silicone with 95 shore hardness, acrylic wafers, and wax recordings. The recordings were obtained in four jaw relations differing in vertical and protrusive components. RESULTS: Of the three materials/material combinations examined, silicone showed the most consistent results across all measurements, followed by the acrylic wafer system, and then wax recordings. Generally, recordings with smaller gaps between the jaws and no protrusive components showed greater deviations compared to jaw positions with greater protrusion and higher vertical dimensions. CONCLUSIONS AND CLINICAL RELEVANCE: To achieve reliable model mounting with high accuracy, recordings should include the use of a frontal jig and four small recording platelets made of silicone, especially if only a slight elevation of the vertical dimension is needed.


Assuntos
Articuladores Dentários , Mandíbula , Humanos , Registro da Relação Maxilomandibular/métodos , Dimensão Vertical , Silicones
16.
Med Image Anal ; 94: 103152, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38531210

RESUMO

Today, fitting bespoke hearing aids involves injecting silicone into patients' ears to produce ear canal molds. These are subsequently 3D scanned to create digital ear canal impressions. However, before digital impressions can be used they require a substantial amount of effort in manual 3D editing. In this article, we present computational methods to pre-process ear canal impressions. The aim is to create automation tools to assist the hearing aid design, manufacturing and fitting processes as well as normalizing anatomical data to assist the study of the outer ear canal's morphology. The methods include classifying the handedness of the impression into left and right ear types, orienting the geometries onto the same coordinate system sense, and removing extraneous artifacts introduced by the silicone mold. We investigate the use of convolutional neural networks for performing these semantic tasks and evaluate their accuracy using a dataset of 3000 ear canal impressions. The neural networks proved highly effective at performing these tasks with 95.8% adjusted accuracy in classification, 92.3% within 20° angular error in registration and 93.4% intersection over union in segmentation.


Assuntos
Meato Acústico Externo , Auxiliares de Audição , Humanos , Meato Acústico Externo/anatomia & histologia , Silicones , Redes Neurais de Computação
17.
Respir Investig ; 62(3): 449-454, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38522361

RESUMO

BACKGROUND: The endobronchial silicone spigot, also known as the endobronchial Watanabe spigot, is used in bronchoscopic interventions to manage prolonged pulmonary air leakage. However, the outcomes of this procedure have not been thoroughly investigated. METHODS: Using a Japanese national inpatient database from April 2014 to March 2022, we assessed the clinical characteristics and outcomes of all eligible patients who received the endobronchial spigot. We also investigated risk factors associated with treatment failure. Treatment failure was defined as in-hospital death or the need for surgery after bronchial occlusion. RESULTS: We analyzed data of 1095 patients who underwent bronchial occlusion using the endobronchial spigot. Among them, 252 patients (23.0%) died during hospitalization, and 403 patients (36.8%) experienced treatment failure. Factors associated with treatment failure included age between 85 and 94 years (odds ratio [OR] 1.83; 95% confidence intervals [CI], 1.04-3.21); male sex (OR 2.43; 95% CI, 1.44-4.11); low Barthel index score; comorbidities of interstitial pneumonia (OR 1.71; 95% CI, 1.18-2.48); antibiotics treatment (OR 1.45; 95% CI, 1.02-2.07); steroids treatment (OR 1.59; 95% CI, 1.07-2.36); and surgery prior to bronchial occlusion (OR 2.08; 95% CI, 1.29-3.35). In contrast, pleurodesis after bronchial occlusion (OR 0.49; 95% CI, 0.32-0.75), and admission to high-volume hospitals were inversely associated with treatment failure (OR 0.58; 95% CI, 0.37-0.90). CONCLUSIONS: The endobronchial Watanabe spigot could be a nonsurgical treatment option for patients with prolonged pulmonary air leaks. Our findings will help identify patients who may benefit from such bronchial interventions.


Assuntos
Obstrução das Vias Respiratórias , Pneumotórax , Humanos , Masculino , Idoso de 80 Anos ou mais , Broncoscopia/métodos , Pneumotórax/epidemiologia , Pneumotórax/etiologia , Pneumotórax/terapia , Silicones , Mortalidade Hospitalar , Resultado do Tratamento , Falha de Tratamento , Fatores de Risco
18.
Int Ophthalmol ; 44(1): 136, 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38485796

RESUMO

BACKGROUND: The surface wettability of soft contact lenses (SCLs) affects the wearing comfort. Verofilcon A is a daily disposable silicone hydrogel contact lens with SMARTSURFACE® technology, ensuring high surface wettability. PURPOSE: To evaluate tear stability on the surface of verofilcon A and narafilcon A SCLs and correlate these findings with clinical parameters and patients' discomfort. METHODS: Sixty-two SCL wearers (124 eyes) with SCL discomfort were randomly assigned to use narafilcon A (control SCL) and verofilcon A for 2 weeks each by crossover. The noninvasive tear break-up time (NIBUT) of the naked eye at baseline and pre-lens NIBUT (PL-NIBUT) of the SCL surface after 2 weeks of using each SCL were measured using the DR-1α® dry eye observation device. Corneal superficial punctate keratopathy (SPK) (0-3) and conjunctival hyperemia (0-3), and comfort level of SCL wear (1-10) were also evaluated. RESULTS: NIBUT and PL-NIBUT values were 4.6 ± 2.3 s for the naked eye, 6.6 ± 6.6 s for narafilcon A, and 11.3 ± 3.5 s for verofilcon A. verofilcon A had significantly higher PL-NIBUT than the naked eye and narafilcon A (p < 0.05). SPK (0.16 ± 0.48 vs. 0.00 ± 0.00, p < 0.01) and conjunctival hyperemia (1.15 ± 0.82 vs. 0.49 ± 0.50, p < 0.01) scores were lower when wearing verofilcon A than narafilcon A. The ocular comfort score of wearing SCLs was higher with verofilcon A than with narafilcon A (8.7 ± 1.8 vs. 9.8 ± 0.5, p < 0.01). The ocular comfort score for wearing verofilcon A was higher, regardless of the baseline NIBUT. CONCLUSION: The results of this study showed a consistent surface-wetting advantage of verofilcon A in patients with ocular discomfort. verofilcon A was used comfortably in patients with low NIBUT scores at baseline. The findings suggest that verofilcon A is recommended for SCL wearers experiencing SCL-related dry eye symptoms and discomfort.


Assuntos
Lentes de Contato Hidrofílicas , Síndromes do Olho Seco , Hiperemia , Humanos , Hidrogéis , Silicones , Síndromes do Olho Seco/etiologia , Lágrimas
19.
Eur Radiol Exp ; 8(1): 36, 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38480588

RESUMO

BACKGROUND: Accurate assessment of breast implants is important for appropriate clinical management. We evaluated silicone properties and diagnostic accuracy for characterizing silicone implants and detecting degenerative changes including rupture in photon-counting computed tomography (PCCT). METHODS: Over 16 months, we prospectively included patients with silicone implants and available breast magnetic resonance imaging (MRI) who received thoracic PCCT performed in prone position. Consensus reading of all available imaging studies including MRI served as reference standard. Two readers evaluated all implants in PCCT reconstructions for degenerative changes. In a subgroup of implants, mean density of silicone, adjacent muscle, and fat were measured on PCCT reconstructions. Contrast-to-noise ratios (CNRs) were calculated for implant-to-muscle and implant-to-fat. RESULTS: Among 21 subjects, aged 60 ± 13.1 years (mean ± standard deviation) with 29 implants PCCT showed the following: high accuracy for linguine sign, intraimplant fluid (all > 0.99), peri-implant silicone (0.95), keyhole sign (0.90), and folds of the membrane (0.81); high specificity for linguine sign, intraimplant fluid, keyhole sign, folds of the membrane (all > 0.99), and peri-implant silicone (0.98); and high sensitivity for linguine sign and intraimplant fluid (all > 0.99). In a subgroup of 12 implants, the highest CNR for implant-to-muscle was observed on virtual unenhanced reconstructions (20.9) and iodine maps (22.9), for implant-to-fat on iodine maps (27.7) and monoenergetic reconstructions (31.8). CONCLUSIONS: Our findings demonstrate that silicone breast implants exhibit distinct contrast properties at PCCT, which may provide incremental information for detection of degenerative changes and rupture of implants. RELEVANCE STATEMENT: Thoracic photon-counting computed tomography is a promising modality for the diagnostic assessment of silicone breast implants. KEY POINTS: • Thoracic photon-counting computed tomography demonstrates unique contrast properties of silicone breast implants. • Iodine map reconstructions reveal strong contrast-to-noise ratios for implant-to-muscle and implant-to-fat. • Thoracic photon-counting computed tomography shows high diagnostic accuracy in detecting implant degeneration and rupture. TRIAL REGISTRATION: German Clinical Trials Register number DRKS00028997, date of registration 2022-08-08, retrospectively registered.


Assuntos
Implantes de Mama , Iodo , Humanos , Implantes de Mama/efeitos adversos , Projetos Piloto , Silicones , Tomografia Computadorizada por Raios X , Pessoa de Meia-Idade , Idoso , Feminino
20.
Environ Sci Technol ; 58(12): 5229-5243, 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38466915

RESUMO

Silicone-based passive samplers, commonly paired with gas chromatography-mass spectrometry (GC-MS) analysis, are increasingly utilized for personal exposure assessments. However, its compatibility with the biotic exposome remains underexplored. In this study, we introduce the wearable silicone-based AirPie passive sampler, coupled with nontargeted liquid chromatography with high-resolution tandem mass spectrometry (LC-HRMS/MS), GC-HRMS, and metagenomic shotgun sequencing methods, offering a comprehensive view of personalized airborne biotic and abiotic exposomes. We applied the AirPie samplers to 19 participants in a unique deep underwater confined environment, annotating 4,390 chemical and 2,955 microbial exposures, integrated with corresponding transcriptomic data. We observed significant shifts in environmental exposure and gene expression upon entering this unique environment. We noted increased exposure to pollutants, such as benzenoids, polycyclic aromatic hydrocarbons (PAHs), opportunistic pathogens, and associated antibiotic-resistance genes (ARGs). Transcriptomic analyses revealed the activation of neurodegenerative disease-related pathways, mostly related to chemical exposure, and the repression of immune-related pathways, linked to both biological and chemical exposures. In summary, we provided a comprehensive, longitudinal exposome map of the unique environment and underscored the intricate linkages between external exposures and human health. We believe that the AirPie sampler and associated analytical methods will have broad applications in exposome and precision medicine.


Assuntos
Expossoma , Doenças Neurodegenerativas , Hidrocarbonetos Policíclicos Aromáticos , Dispositivos Eletrônicos Vestíveis , Humanos , Espaços Confinados , Transcriptoma , Monitoramento Ambiental/métodos , Silicones
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...